AMS Global Garment Storage Cabinet (GSC) is designed to provide ISO Class 5 (Class 100) particle free work area to meet sterile garment storage needs which avoids any particulate accumulation. The work area is continuously supplied with positive pressure HEPA filtered re-circulated vertical/ horizontal air flow.

An integral HEPA filter and blower assembly provides a continuous wash of class 100 air over the garments.

  • Material of Construction : Powder Coated MS / GI / SS 304 / SS 316 / SS 316 L
  • Class 100 Compatible
  • Two Stage filtration
  • U.V Light with Hour Meter
  • Heater with thermostat
  • Interlocking arrangement to put-off U.V. Light if either door opens.
  • EU6- Pre filter (95% down to 5 micron) for return air & fresh air intake
  • EU13-HEPAFilter (99.97% down to 0.3 micron) at supply position
  • Statically & Dynamically balanced Motor-blower with suspension arrangement to reduce noise level
  • Differential Pressure Gauge: 1 No.
  • SS304 Hanging Arrangement/ SS304 removable Shelves
  • SS304 doors with double walled flush glass view panels
  • ON/OFF Switches
  • PAO Test Port
  • 5/15 Amp Switch Socket for external equipment
  • PU Caster wheels for easy movement
  • Leg levelers in SS304

SUCTION FILTER :-

  • Filter Casing- AL flange type.
  • Efficiency- 95% down to 5 microns (EU-4 Rating.)
  • Media- Non-woven synthetic media sandwiched between two layers of High Density
  • Polyethylene Mesh

SUPPLY FILTER: –

  • Filter Casing- Aluminum factory extruded section.
  • Efficiency- (99.997% down to 0.3 micron)
  • Media- Micro fiberglass paper media (Imported) pleated along with Hot Melt Glue.
  • Air cleanliness: ISO Class 5 (ISO 14644-1:1999 (E))
  • Air Velocities: 0.45 ± 0.05 MPS
  • Air Flow: Vertical/Horizontal-Re-circulatory (Based on application)
  • Noise Level: Less than 67 dB
  • Vibration Level: Minimum
  • Power Supply: 230V AC 1- Ø 50HZ
  • Electric Motor-double ended shaft, Single phase, 240 volts, 50Hz.
  • Impellers-Aluminum, statically & dynamically balanced, forward curve type.
  • Blower casings- AL / GI / MS, centrifugal type.
  • Magnehelic pressure gauge for checking the pressure drop across the supply Minipleat Hepa
  • Filters. Range- 0 TO 25 / 50 mm of WC.
  • Hour meter connected to UV light.
  • PU caster with s.s.body and front lockable type wheel.
  • S.S.304 levelers for height adjustment.
  • Infra-Red light (Optional)
  • Feather touch ON/OFF switches for b/w motor, tube light, UV light & aux. socket with light
  • Indication.
  • LED light & UV light along with Hour meter.
  • Three-pin top along with connection cable.
  • A wide range of configurations to suit any containment application
  • Blower tripping alarms (audible and visible)
  • Velocity display with alarms (audible and visible)
  • Filter blocked alarms (audible and visible)
  • Explosion proof electrics for Flame-proof applications